Smartdhome heat/cool meters from the MyHCM2 series, MID certified, are ideal for thermal energy metering—both heating and cooling—and use ultrasonic technology to ensure maximum reading stability over time.
| Power Supply: Built-in Li-Ion batteries |
| Battery Life: 22 years |
| Communication Protocol: Modbus RS485 RTU Slave |
| Metrological Class: Class 2 (EN1434) and (2004/22/EC MID) |
| Detectable Temperature: 4°C ~ 95°C |
| Connection: DN40 (G2") |
| Nominal Flow Rate qp (m3/h): 10.0 |
| Minimum Flow Rate qi (m3/h): 0.2 |
| Maximum Flow Rate (m3/h): 20.0 |
| Maximum Operating Pressure: 1.6Mpa |
| Pressure Loss: △P<25kPa at qp |
| Nominal Pressure PN: 16 bar |
| Temperature Sensor: 2 platinum PT 1000 (cable length 1.5m) |
| Certifications: CE and ROHS |
| Display: LCD |
| Data Storage: 36 months |
| Programming: Optical port |
| Protection Rating: IP65 |
| Operating Temperature: -25°C ~ 55°C |
| Installation: Horizontal or vertical |
| Dimensions: 200 mm (L) x 118 mm (H) x 105 mm (D) |
| Weight: |
| Product Code: 01336-5045-00 |
| Sales Unit: 1 |
| Package Contents: Ultrasonic heat/cool meter MyHCM2 DN40 nominal flow rate 10.0 m³/h with Modbus interface and MID certification, user manual |
| Power Supply: Built-in Li-Ion batteries |
| Battery Life: 22 years |
| Communication Protocol: Modbus RS485 RTU Slave |
| Metrological Class: Class 2 (EN1434) and (2004/22/EC MID) |
| Detectable Temperature: 4°C ~ 95°C |
| Connection: DN32 (G1 1/2") |
| Nominal Flow Rate qp (m3/h): 6.0 |
| Minimum Flow Rate qi (m3/h): 0.12 |
| Maximum Flow Rate (m3/h): 12.0 |
| Maximum Operating Pressure: 1.6Mpa |
| Pressure Loss: △P<25kPa at qp |
| Nominal Pressure PN: 16 bar |
| Temperature Sensor: 2 platinum PT 1000 (cable length 1.5m) |
| Certifications: CE and ROHS |
| Display: LCD |
| Data Storage: 36 months |
| Programming: Optical port |
| Protection Rating: IP65 |
| Operating Temperature: -25°C ~ 55°C |
| Installation: Horizontal or vertical |
| Dimensions: 180 mm (L) x 114 mm (H) x 105 mm (D) |
| Weight: |
| Product Code: 01336-5040-00 |
| Sales Unit: 1 |
| Package Contents: Ultrasonic heat/cool meter MyHCM2 DN32 nominal flow rate 6.0 m³/h with Modbus interface and MID certification, user manual |